Durlon® 9002 is an adaptation of the original glass-filled formula to better meet extreme cryogenic system demands. Durlon® 9002 has passed both gaseous, [up to 260°C (500°F) and 52 bar (754 psi)] and liquid oxygen tests performed by BAM Federal Institute for Materials Research and Testing. Durlon® 9002 has also been tested for LOX Mechanical Impact Sensitivity, passing with zero reactions out of twenty tests (0/20) at a test reaction frequency of 0%.
Durlon® 9002 is readily available through the standard manufacturing process and requires no secondary heat or cleansing treatments prior to gasket cutting. Once gaskets are cut, traditional oxygen cleaning standards must be applied for safety. Durlon® 9002 comes available as oxygen cleaned gaskets, bagged, labeled, and sealed according to the European Industrial Gases Association standard for Cleaning of Equipment for Oxygen Service.